| Type |
URE-300 |
| Input (DC) |
| Max Recommended PV Power (Wp) |
300 |
| Max DC Open Circuit Voltage (Vdc) |
60 |
| Max DC Input Current (Adc) |
12 |
| MPPT Tracking Accuracy |
>99.5% |
| MPPT Tracking Range (Vdc) |
22-55 |
| Isc PV (absolute maximum) (Adc) |
14 |
| Maximum Inverter Backfeed Current to the Array (Adc) |
0 |
| Output (AC) |
| Rated AC Output power (Wp) |
250 |
| Nominal power Grid Voltage (Vac) |
240 |
| Allowable Power Grid Voltage (Vac) |
|
| Allowable Power Grid Frequency (Hz) |
59.3-60.5* |
| THD |
<3% (at rated power) |
| Power Factor (cos phi, fixed) |
>0.99% at rated power |
| Rated Output Current (Aac) |
| 1.04 |
1.20 |
1.09 |
2.08 |
2.40 |
2.17 |
|
| Current (inrush) (Peak and Duration) |
12A, 15us |
| Nominal Frequency (Hz) |
|
| Maximum Output Fault Current (Aac) |
2.2A peak |
| Maximum Output Over current Protection (Aac) |
6.3 |
| Max. Number of Units Per Branch (20A/15A circuit) |
| 15/11 |
13/11 |
14/11 |
7/5 |
6/5 |
7/5 |
|
| System Efficiency |
| Weighted Averaged Efficiency (CEC) |
95% |
| Night Time Tare Loss (Wp) |
0.17 |